Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Acta Orthop ; 95: 157-165, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38597226

RESUMEN

BACKGROUND AND PURPOSE:  Different marker-selection methods are applied to represent implant and tibial segments in radiostereometric analysis (RSA) studies of total knee arthroplasty (TKA). Either a consistent set of markers throughout subsequent RSA examinations ("consistent-marker method") is used or all available markers at each follow-up ("all-marker method"). The aim of this secondary analysis was to compare marker-selection methods on individual and group level TKA migration results. METHODS:  Data from a randomized RSA study with 72 patients was included. Tibial baseplate migration was evaluated at 3 months, 1, 2, and 5 years postoperatively with both marker-selection methods. Additionally, migration was calculated using 5 fictive points, either plotted based on the consistent set of markers or all available markers. RESULTS:  Migration could be calculated with both marker-selection methods for 248 examinations. The same prosthesis and bone markers (n = 136), different prosthesis markers (n = 71), different bone markers (n = 21), or different prosthesis and bone markers (n = 20) were used. The mean difference in maximum total point motion (MTPM) between all examinations was 0.02 mm, 95% confidence interval -0.26 to 0.31 mm. 5 implants were classified as continuously migrating with the consistent-marker method versus 6 implants (same 5 plus one additional implant) with the all-marker method. Using fictive points, fewer implants were classified as continuously migrating in both marker-selection methods. Differences between TKA groups in mean MTPM were comparable with both marker-selection methods, also when fictive points were used. CONCLUSION:  Estimated group differences in mean MTPM were similar between marker-selection methods, but individual migration results differed. The latter has implications when classifying implants for estimated risk of future loosening.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Estudios de Seguimiento , Análisis Radioestereométrico , Falla de Prótesis , Diseño de Prótesis , Osteoartritis de la Rodilla/cirugía
2.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1253-1263, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38488225

RESUMEN

PURPOSE: This clinical fluoroscopy study investigated knee kinematics of two different cemented fixed-bearing, posterior-stabilised (PS) total knee arthroplasty (TKA) designs: an asymmetric tibial component including an asymmetric insert designed to optimise personalised balance and fit and its precursor symmetrical design with symmetric insert. METHODS: A consecutive series of patients (16 TKAs from each treatment group) participating in a randomised controlled trial comparing TKA migration was included. The exclusion criterion was the use of walking aids. Flat-panel fluoroscopic recordings of step-up and lunge motions were acquired 1-year postoperatively. Medial and lateral contact points (CPs) were determined to calculate CP displacement, femoral axial rotation and pivot position. Using linear mixed-effects modelling techniques, kinematics between TKA designs were compared. RESULTS: During knee extension between 20° flexion and full extension, the CPs moved anteriorly combined with a small internal femoral rotation (a screw-home mechanism). Whereas CP movement was reversed: femoral rollback, external femoral rotation while flexing the knee between full extension and 20° knee flexion, At larger flexion angles, femoral axial rotation (FAR) occurred around a lateral pivot point both during step-up and lunge. The symmetric design had a 2.3° larger range of FAR compared to the asymmetric design during lunge (p = 0.02). All other kinematics were comparable. CONCLUSION: Despite the differences in design, this study showed that the asymmetric and symmetric PS TKA designs had mostly comparable knee kinematics during step-up and lunge motions. It is therefore expected that the functionality of the successor TKA design is similar to that of its precursor design. LEVEL OF EVIDENCE: Level II, prospective comparative study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Diseño de Prótesis , Rango del Movimiento Articular , Tibia , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Fluoroscopía , Fenómenos Biomecánicos , Femenino , Masculino , Anciano , Tibia/cirugía , Persona de Mediana Edad , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Rotación , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/fisiopatología
3.
Bone Joint J ; 106-B(2): 136-143, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38295835

RESUMEN

Aims: The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface. Methods: Overall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating. All components were used in combination with a cemented Exeter V40 femoral stem. Implant migration was measured using radiostereometric analysis (RSA), with radiographs taken within two days of surgery (baseline), and at three, 12, and 24 months postoperatively. Proximal acetabular component migration was the primary outcome measure. Clinical scores and patient-reported outcome measures (PROMs) were collected at each follow-up. Results: Mean proximal migrations at three, 12, and 24 months were 0.08 mm (95% confidence interval (CI) 0.03 to 0.14), 0.11 mm (95% CI 0.06 to 0.16), and 0.14 mm (95% CI 0.09 to 0.20), respectively, in the Trident II HA group, versus 0.11 mm (95% CI 0.06 to 0.16), 0.12 mm (95% CI 0.07 to 0.17), and 0.14 mm (95% CI 0.09 to 0.19) in the Trident HA group (p = 0.875). No significant differences in translations or rotations between the two designs were found in any other direction. Clinical scores and PROMs were comparable between groups, except for an initially greater postoperative improvement in Hip disability and Osteoarthritis Outcome Symptoms score in the Trident HA group (p = 0.033). Conclusion: The Trident II clusterhole HA shell has comparable migration with its predecessor, the Trident hemispherical HA cluster shell, suggesting a similar risk of long-term aseptic loosening.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Durapatita , Análisis Radioestereométrico , Titanio , Estudios de Seguimiento , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
4.
Bone Joint J ; 105-B(11): 1168-1176, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37907075

RESUMEN

Aims: Conflicting clinical results are reported for the ATTUNE Total Knee Arthroplasty (TKA). This randomized controlled trial (RCT) evaluated five-year follow-up results comparing cemented ATTUNE and PFC-Sigma cruciate retaining TKAs, analyzing component migration as measured by radiostereometric analysis (RSA), clinical outcomes, patient-reported outcome measures (PROMs), and radiological outcomes. Methods: A total of 74 primary TKAs were included in this single-blind RCT. RSA examinations were performed, and PROMs and clinical outcomes were collected immediate postoperatively, and at three, six, 12, 24, and 60 months' follow-up. Radiolucent lines (RLLs) were measured in standard anteroposterior radiographs at six weeks, and 12 and 60 months postoperatively. Results: At five-year follow-up, RSA data from 61 patients were available and the mean maximum total point motion (MTPM) of the femoral components were: ATTUNE: 0.96 mm (95% confidence interval (CI) 0.79 to 1.14) and PFC-Sigma 1.37 mm (95% CI 1.18 to 1.59) (p < 0.001). The PFC-Sigma femoral component migrated more in the first postoperative year, but stabilized thereafter. MPTM of the tibial components were comparable at five-year follow-up: ATTUNE 1.12 mm (95% CI 0.95 to 1.31) and PFC-Sigma 1.25 mm (95% CI 1.07 to 1.44) (p = 0.438). RLL at the medial tibial implant-cement interface remained more prevalent for the ATTUNE at five-year follow-up compared to the PFC-Sigma (20% vs 3%). RLL did not progress over time, and varied between patients at different timepoints for both TKA systems. Clinical outcomes and PROMs improved compared with preoperative scores, and were not different between groups. Conclusion: MTPM migration at five-year follow-up of the femoral and tibial component of the ATTUNE were similar and as low as that of the PFC-Sigma. MTPM migration of both knee implants did not significantly change from one year post-surgery, indicating stable fixation. Long-term ATTUNE performance may be expected to be comparable to the clinically well-performing PFC-Sigma. We have not found evidence of increased tibial component migration as measured by RSA to support concerns about cement debonding and a higher risk of aseptic loosening with the ATTUNE TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Análisis Radioestereométrico/métodos , Resultado del Tratamiento , Osteoartritis de la Rodilla/cirugía , Estudios de Seguimiento , Cementos para Huesos , Diseño de Prótesis , Falla de Prótesis , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía
5.
Bone Joint J ; 105-B(2): 148-157, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36722052

RESUMEN

AIMS: The primary aim of this study was to compare the migration of the femoral and tibial components of the cementless rotating platform Attune and Low Contact Stress (LCS) total knee arthroplasty (TKA) designs, two years postoperatively, using radiostereometric analysis (RSA) in order to assess the risk of the development of aseptic loosening. A secondary aim was to compare clinical and patient-reported outcome measures (PROMs) between the designs. METHODS: A total of 61 TKAs were analyzed in this randomized clinical RSA trial. RSA examinations were performed one day and three, six, 12, and 24 months postoperatively. The maximal total point motion (MPTM), translations, and rotations of the components were analyzed. PROMs and clinical data were collected preoperatively and at six weeks and three, six, 12, and 24 months postoperatively. Linear mixed effect modelling was used for statistical analyses. RESULTS: The mean MTPM two years postoperatively (95% confidence interval (CI)) of the Attune femoral component (0.92 mm (0.75 to 1.11)) differed significantly from that of the LCS TKA (1.72 mm (1.47 to 2.00), p < 0.001). The Attune femoral component subsided, tilted (anteroposteriorly), and rotated (internal-external) significantly less. The mean tibial MTPM two years postoperatively did not differ significantly, being 1.11 mm (0.94 to 1.30) and 1.17 mm (0.99 to 1.36, p = 0.447) for the Attune and LCS components, respectively. The rate of migration in the second postoperative year was negligible for the femoral and tibial components of both designs. The mean pain-at-rest (numerical rating scale (NRS)-rest) in the Attune group was significantly less compared with that in the LCS group during the entire follow-up period. At three months postoperatively, the Knee injury and Osteoarthritis Outcome Physical Function Shortform score, the Oxford Knee Score, and the NRS-activity scores were significantly better in the Attune group. CONCLUSION: The mean MTPM of the femoral components of the cementless rotating platform Attune was significantly less compared with that of the LCS design. This was reflected mainly in significantly less subsidence, posterior tilting, and internal rotation. The mean tibial MTPMs were not significantly different. During the second postoperative year, the components of both designs stabilized and low risks for the development of aseptic loosening are expected.Cite this article: Bone Joint J 2023;105-B(2):148-157.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Traumatismos de la Rodilla , Osteoartritis , Humanos , Fémur/diagnóstico por imagen , Fémur/cirugía , Tibia/cirugía
6.
Clin Biomech (Bristol, Avon) ; 100: 105824, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36435077

RESUMEN

BACKGROUND: There is no consensus on the importance of the kinematics of the prosthetic joint for the clinical outcome after total knee arthroplasty. A 3-armed randomized controlled trial was done to determine and compare the in vivo kinematics of a posterior cruciate-retaining and two posterior cruciate-sacrificing (Anterior-Stabilized and Posterior-Stabilized) prosthetic designs from the same total knee arthroplasty system. Since the anterior-stabilized and posterior-stabilized designs are posterior cruciate ligament-sacrificing designs, we hypothesized they would have similar contact-point kinematics. Further, we hypothesized that the cruciate-retaining design would have contact-point kinematics different from the anterior-stabilized and the posterior-stabilized designs, but comparable to a native knee. METHODS: Thirty-nine patients with a well-functioning total knee arthroplasty one year postoperatively underwent kinematic analysis of a weight-bearing step-up movement under fluoroscopic recording. Model-based radiostereometric analysis was used to determine anteroposterior contact-point translations and rotations through the movement path to assess knee kinematics. FINDINGS: The cruciate-retaining and anterior-stabilized groups' medial and lateral contact-points displayed similar paradoxical posterior translations during step-up in the magnitude of 7 and 2 mm, respectively. In contrast, the posterior-stabilized group's contact-points translated anteriorly by 4 and 10 mm throughout the movement and were significantly more posterior than the cruciate-retaining and the anterior-stabilized groups from >100° to 40° of flexion. The femur rotated internally with all designs. INTERPRETATION: The cruciate-retaining and anterior-stabilized designs displayed similar contact-point translation patterns during a step-up movement. Only the posterior-stabilized design showed a pattern comparable to native knees. Conversion from a cruciate-retaining to an anterior-stabilized design because of posterior cruciate ligament insufficiency will not change knee kinematics.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Humanos , Diseño de Prótesis
7.
Acta Orthop ; 93: 451-458, 2022 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-35485295

RESUMEN

BACKGROUND AND PURPOSE: Ceramic liners may reduce early stability of uncemented acetabular components due to higher stiffness. However, the bone ingrowth capacities of porous trabecular titanium might compensate for this effect. This prospective randomized trial quantifies migration patterns of the Delta-TT cup, and compares polyethylene and ceramic liners. PATIENTS AND METHODS: Patients undergoing primary uncemented total hip arthroplasty with the Delta-TT cup and femoral stem with ceramic head were randomized to a polyethylene (n = 25) or ceramic (n = 28) liner. Radiostereometric analysis (RSA) radiographs, patient-reported hip function (HOOS-PS, OHS), and quality of life (EQ5D) were collected at baseline and 1.5, 3, 6, 12, and 24 months postoperatively. Model-based RSA was used to calculate 3D cup translation and rotation, and mixed models were used to compare effects over time between groups. RESULTS: At 2 years follow-up, Delta-TT cups showed similar mean proximal translation of 0.56 mm (95% CI 0.38-0.75) in the ceramic (CE) group and 0.54 mm (0.30-0.77) in the polyethylene (PE) group, with a between group effect of 0.02 mm (-0.20-0.23). Most cup migration occurred in the first 1.5 to 3 months, stabilizing within 6 months. Any between-group effects were ≤ 0.30 mm for translation and ≤ 0.45° for rotation. Improvements in patient-reported hip function and quality of life were similar in both groups. INTERPRETATION: Regardless of liner type, Delta-TT cups showed some initial migration and stabilized within 6 months, which seems promising for long-term fixation in both cup-liner constructs.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Cerámica , Humanos , Polietileno , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Calidad de Vida , Análisis Radioestereométrico , Titanio
9.
Acta Orthop ; 93: 212-221, 2022 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-34984483

RESUMEN

Background and purpose - The Taperloc Complete hip is the successor of the Taperloc hip, aiming to increase range of motion and optimizing femoral fit with intermediate stem sizes. We evaluated whether these design changes affect fixation, and this RSA study compares 2-year migration. Patients and methods - In this prospective, multi-arm study, 100 patients were randomized to cementless total hip arthroplasty (THA) with Taperloc Complete full profile (TCFP), Taperloc Complete reduced distal (TCRD), Taperloc full profile (TFP), or Taperloc reduced distal (TRD). Migration was measured with model-based RSA postoperatively, and after 3, 12, and 24 months. Results - Results based on mixed-model analysis on 2-year postoperative RSA data from 74 patients showed similar subsidence (mm) in the first 3 months (mean [95% CI] TCFP 0.44 [0.20-0.69], TCRD 0.91 [0.40-1.42], TFP 0.71 [0.22-1.19], TRD 1.25 [0.58-1.91]) and stabilization afterwards. The TCFP showed statistically significantly less retroversion (°) at 2-year postoperatively compared with TFP and TCRD (mean [95% CI] TCFP: -0.13 [-0.64 to 0.38], TCRD: 0.84 [0.35-1.33], TFP: 0.56 [0.12-1.00], TRD: 0.37 [-0.35 to 1.09]). Interpretation - As expected in successful cementless THA, RSA shows stabilization after initial subsidence. Based on these results the Taperloc Complete stem is expected to have similar long-term fixation to the Taperloc stems. The reduced distal groups have larger, but statistically non-significant, initial migration compared with the TCFP group, which could be due to implantation in Dorr B, C femur types. It may be important to consider the femur shape for choosing a full profile or reduced distal stem to minimize migration.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Fémur/cirugía , Estudios de Seguimiento , Humanos , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Análisis Radioestereométrico
10.
Foot Ankle Int ; 43(5): 637-645, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34962173

RESUMEN

BACKGROUND: Mixed results for functional outcomes and long-term fixation have been reported for first metatarsophalangeal arthroplasty. This prospective study was designed to evaluate the migration of the BioPro metatarsophalangeal-1 (MTP-1) joint hemiprosthesis with Roentgen stereophotogrammetric analysis (RSA). Migration patterns of the prosthesis, prosthesis-induced erosion of the metatarsal bone, and clinical outcomes were evaluated sequentially to 5 years postoperation (PO). METHODS: Eleven female patients received the BioPro-1 hemiprosthesis. Prosthesis translation and metatarsal erosion were measured with RSA at immediately PO, 6 weeks, and 3, 6, 12, 36, and 60 months postoperatively. Clinical assessment was done by patient questionnaires. RESULTS: RSA data of 9 patients were available for analysis. Median (range) number of markers used in RSA analysis, condition number, and mean error of markers around the prosthesis were 4 (3-7), 320 (208-862), and 0.13 (0.02-0.28), respectively. Progressive subsidence was seen up to 3 years PO (mean 2.1 mm, SE 0.32). Progressive metatarsal erosion was found from 1 year PO (mean 0.49 mm, SE 0.15). Pain, function, and quality scores improved after surgery and did not deteriorate at later follow-up moments. CONCLUSION: Model-based RSA of the BioPro-1 prosthesis shows nonstabilizing medial and distal translation and metatarsal erosion. Despite the measured migration and erosion, clinical outcomes improved and remained similar up to 5 years postoperation. LEVEL OF EVIDENCE: Level II, prospective analysis of MTP-1 hemiprosthesis.


Asunto(s)
Hallux Rigidus , Hemiartroplastia , Huesos Metatarsianos , Articulación Metatarsofalángica , Femenino , Estudios de Seguimiento , Hallux Rigidus/cirugía , Hemiartroplastia/métodos , Humanos , Huesos Metatarsianos/cirugía , Articulación Metatarsofalángica/diagnóstico por imagen , Articulación Metatarsofalángica/cirugía , Estudios Prospectivos , Resultado del Tratamiento
11.
Bone Joint J ; 103-B(5): 855-863, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33934647

RESUMEN

AIMS: The objective of this study was to compare the two-year migration pattern and clinical outcomes of a total knee arthroplasty (TKA) with an asymmetrical tibial design (Persona PS) and a well-proven TKA with a symmetrical tibial design (NexGen LPS). METHODS: A randomized controlled radiostereometric analysis (RSA) trial was conducted including 75 cemented posterior-stabilized TKAs. Implant migration was measured with RSA. Maximum total point motion (MTPM), translations, rotations, clinical outcomes, and patient-reported outcome measures (PROMs) were assessed at one week postoperatively and at three, six, 12, and 24 months postoperatively. RESULTS: A linear mixed-effect model using RSA data of 31 asymmetrical and 38 symmetrical TKAs did not show a difference in mean MTPM migration pattern of the tibial or femoral components. Mean tibial component MTPM at two years postoperative of the asymmetrical TKA design was 0.93 mm and 1.00 mm for the symmetrical design. For the femoral component these values were 1.04 mm and 1.14 mm, respectively. No significant differences were observed in other migration parameters or in clinical and PROM measurements. CONCLUSION: The TKA design with an asymmetrical tibial component has comparable component migration with the proven TKA with a symmetrical tibial component. This suggests the risk of long-term aseptic loosening of the two designs is comparable. Cite this article: Bone Joint J 2021;103-B(5):855-863.


Asunto(s)
Migración de Cuerpo Extraño/diagnóstico por imagen , Prótesis de la Rodilla , Diseño de Prótesis , Análisis Radioestereométrico , Adulto , Anciano , Anciano de 80 o más Años , Artritis Reumatoide/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Medición de Resultados Informados por el Paciente , Estudios Prospectivos , Falla de Prótesis
12.
BMC Musculoskelet Disord ; 22(1): 148, 2021 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-33546653

RESUMEN

BACKGROUND: The aim of this study was to determine long-term survival and clinical outcomes of the surface replacement trapeziometacarpal joint prosthesis (SR™TMC) and to evaluate implant migration using radiostereometric analysis (RSA). METHODS: In this clinical long-term follow-up study outcomes of ten patients who received the SR™TMC joint prosthesis were evaluated using DASH and Nelson scores, Visual Analogue Scale (VAS) of pain, and key pinch strength. RSA-radiographs were obtained direct postoperatively and 6 months, 1, 5 and 10 years postoperatively and were analyzed using model-based RSA software. RESULTS: During follow-up, two early revisions took place. Mean pre-operative DASH and Nelson scores were 54 (SD 15) and 54 (SD 17), improved significantly after 6 months (DASH 25 (SD 20), Nelson 75 (SD 18)) and remained excellent during long-term follow-up in all patients with a stable implant. At final follow-up, clinical scores deteriorated clearly in two patients with a loose implant in situ. CONCLUSIONS: Long-term survival of the SR™TMC joint prosthesis is relatively poor. However, clinical outcomes improved significantly in the short-term and remained excellent in the long-term in those patients with a stable implant, but deteriorated clearly in case of loosening. The role of RSA in TMC joint arthroplasty is potentially valuable but needs to be further investigated. Several challenges of RSA in the TMC joint have been addressed by the authors and suggestions to optimize RSA-data are given. TRIAL REGISTRATION: This study was registered in the Netherlands Trial Register ( NL7126 ).


Asunto(s)
Prótesis Articulares , Osteoartritis , Estudios de Seguimiento , Humanos , Países Bajos , Osteoartritis/diagnóstico por imagen , Osteoartritis/cirugía , Diseño de Prótesis , Falla de Prótesis , Análisis Radioestereométrico
13.
J Patient Exp ; 7(4): 484-492, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33062868

RESUMEN

BACKGROUND: Compliance rates with patient-reported outcome measures (PROMs) collected alongside arthroplasty registries vary in the literature. We described the feasibility of a routinely collected set PROMs alongside the Dutch Arthroplasty Register. METHODS: The longitudinal Leiden Orthopaedics Outcomes of OsteoArthritis Study is a multicenter (7 hospitals), observational study including patients undergoing total hip or total knee arthroplasty (THA or TKA). A set of PROMs: Short Form-12, EuroQol 5 Dimensions, Hip/Knee injury and Osteoarthritis Outcome Score, Oxford Hip/Knee Score was collected preoperatively and at 6, 12, 24 months, and every 2 years thereafter. Participation rates and response rates were recorded. RESULTS: Between June 2012 and December 2014, 1796 THA and 1636 TKA patients were invited, of whom 1043 THA (58%; mean age 68 years [standard deviation, SD: 10]) and 970 TKA patients (59%; mean age 71 years [SD 9.5]) participated in the study. At 6 months, 35 THA/38 TKA patients were lost to follow-up. Response rates were 90% for THA (898/1000) and 89% for TKA (827/932) participants. At 1 and 2 years, 8 and 18 THA and 17 and 11 TKA patients were lost to follow-up, respectively. The response rates among those eligible were 87% (866/992) and 84% (812/972) for THA and 84% (771/917) and 83% (756/906) for TKA patients, respectively. The 2-year questionnaire was completed by 78.5% of the included THA patients and by 77.9% of the included TKA patients. CONCLUSIONS: About 60% of patients undergoing THA or TKA complete PROMs preoperatively, with more than 80% returning follow-up PROMs. To increase the participation rates, more efforts concerning the initial recruitment of patients are needed.

14.
Acta Orthop ; 91(4): 390-395, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32452270

RESUMEN

Background and purpose - Radiostereometric analysis (RSA) is the gold standard to study micromotion of joint replacements. RSA requires the acquisition of additional radiographs increasing the radiation dose of patients included in RSA studies. It is important to keep this dose as low as possible. Effective radiation dose (ED) measurements of RSA radiographs for different joints were done by Teeuwisse et al. some years ago using conventional radiology (CR); for total hip arthroplasty (THA), Teeuwisse et al. reported an ED of 0.150 milliSievert (mSv). With the modern digital radiography (DR) roentgen technique the ED is expected to be less.Material and methods - In this phantom study, simulating a standard patient, the ED for hip RSA radiographs is determined using DR under a variety of different roentgen techniques. The quality of the RSA radiographs was assessed for feasibility in migration analysis using a (semi-)automatic RSA analysis technique in RSA software.Results - A roentgen technique of 90 kV and 12.5 mAs with additional 0.2 copper (Cu) + 1 mm aluminum (Al) external tube filters results in an ED of 0.043 mSv and radiographs suitable for analysis in RSA software.Interpretation - The accumulated ED for a standard patient in a 2-year clinical hip RSA study with 5 follow-up moments and a double acquisition is below the acceptable threshold of 1.0 mSv provided by the EU radiation guideline for studies increasing knowledge for general health.


Asunto(s)
Articulación de la Cadera/diagnóstico por imagen , Dosis de Radiación , Análisis Radioestereométrico/métodos , Artroplastia de Reemplazo de Cadera/métodos , Humanos , Persona de Mediana Edad , Análisis Radioestereométrico/instrumentación
15.
Acta Orthop ; 90(4): 366-372, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31017513

RESUMEN

Background and purpose - Pooling data of studies evaluating total knee arthroplasty migration using radiostereometric analysis (RSA) may be compromised when the RSA method used would influence estimated differences between groups. We therefore reanalyzed a marker-based RSA study with model-based RSA to assess possible limitations of each RSA method, including insert micromotions in modular TKA and their effect on estimated group differences. Patients and methods - All patients had received a cemented Triathlon implant (Stryker, Mahwah, NJ, USA) with either an all-polyethylene (n = 29) or a metal-backed (n = 28) tibial component. The latter group was reanalyzed with model-based RSA. Precision of each RSA method was calculated using double examinations. Bland-Altman plots were constructed to determine the limits of agreement between the 2 RSA methods. Polyethylene insert micromotion was quantified by measuring migration with respect to the metal tray. Finally, analyses of the original study were repeated with the model-based RSA results. Results - Systematic differences were found in translations between marker-based and model-based RSA as a result of different reference origins being used for migration calculations. Micromotions of the polyethylene insert within the metal tray were negligibly small. Mean migration results were comparable between marker-based and model-based RSA when using the same reference origin, even though conclusions on individual patients may differ between RSA methods due to various types of measurement error (e.g., marker occlusion and model-fit inaccuracies). Interpretation - At least for the studied TKA design, pooling mean migration data of different RSA methods appears justified. For translations, however, adjustments should be made to correct for differences in reference origin. Migration patterns of individual patients may differ as a result of distinct types of measurement error.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Prótesis de la Rodilla/efectos adversos , Falla de Prótesis , Biomarcadores , Humanos , Análisis Radioestereométrico , Factores de Tiempo
16.
Rheumatol Int ; 38(5): 917-924, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29147763

RESUMEN

Frailty is highly prevalent in the elderly, increasing the risk of poor health outcomes. The Groningen Frailty Indicator (GFI) is a 15-item validated questionnaire for the elderly. Its value in patients with end-stage hip or knee osteoarthritis (OA) has not yet been determined. This study assesses the validity of the GFI in this patient group. End-stage hip or knee OA patients completed the GFI (range 0-15, ≥ 4 = frail) before arthroplasty surgery. Convergent validity was determined by Spearman-rank correlation between the SF-12 physical (PCS) and mental (MCS) component scores and the physical and mental GFI-domains, respectively. Discriminant validity was assessed by means of overall GFI-score and the pain-domain of the Hip/Knee Osteoarthritis Outcome Score (HOOS/KOOS). Altogether 3275 patients were included of whom 2957 (90.3%) completed the GFI. Mean GFI-scores were 2.78 (2.41) and 2.28 (1.99) in hip and knee OA-patients, respectively, with 570 (35.9%) of hip and 344 (24.1%) of knee patients considered frail. The convergent validity was moderate to strong (physical domain R = - 0.4, mental domain R = - 0.6) and discriminant validity low (R HOOS/KOOS-pain domain = - 0.2), confirming the validity of the GFI-questionnaire in this population. With 90% of participants completing the GFI, it is a feasible and valid questionnaire to assess frailty in end-stage hip and knee OA-patients. One-third (33.3%) of the patients undergoing hip arthroplasty and a quarter (24.1%) of those undergoing knee arthroplasty are frail. Whether this is associated with worse outcomes and can thus be used as a pre-operative predictor needs to be explored.


Asunto(s)
Fragilidad/diagnóstico , Osteoartritis de la Cadera/diagnóstico , Osteoartritis de la Rodilla/diagnóstico , Encuestas y Cuestionarios , Actividades Cotidianas , Factores de Edad , Anciano , Evaluación de la Discapacidad , Estudios de Factibilidad , Femenino , Anciano Frágil , Fragilidad/fisiopatología , Fragilidad/psicología , Estado de Salud , Humanos , Masculino , Salud Mental , Persona de Mediana Edad , Países Bajos , Osteoartritis de la Cadera/fisiopatología , Osteoartritis de la Cadera/psicología , Osteoartritis de la Cadera/cirugía , Osteoartritis de la Rodilla/fisiopatología , Osteoartritis de la Rodilla/psicología , Osteoartritis de la Rodilla/cirugía , Dimensión del Dolor , Valor Predictivo de las Pruebas , Pronóstico , Calidad de Vida , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...